The newest equipment for electronic water treatment on an environment-friendly basis |
||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
| m |
|
The capacitive as the inductive technique work with frequencies of 1800-16100Hz, with 10Hz phase displacement. Both techniques cause a physical change of the lime molecules, thus the lime loses the ability to adhere as limestone in the pipes, at immersion heaters, heat exchangers, on tiles, armatures etc.. The lime remains in the state of suspension and is rinsed out with the water. The changed structure of the lime crystals remain steady also in warm water, at temperatures up to 97 degrees Celsius, the lime remains in suspension and cannot adhere. The degradation of existing lime crusts in water pipes / solar and heat exchangers, is a procedure, which happens parallel to the actual lime protection. This effect is caused in the upper frequency range of 10.000 to 16.100Hz. |
| without Protector | untreated lime | with Protector | treated lime | |||
![]() |
![]() |
|||||
|
The protector 6.03 technology |
![]() |
| The physical water treatment does not remove the lime from the water but it changes the molecular structure in the water. The chemical composition of the water remains the same. Lime and other minerals as well as trace elements will remain in the water. The taste and the positive characteristics of water will not change. The lime crystals lose their ability to adhere on surface so they will now flow as “suspended matter” in the water | |
| Lime deposits of 5mm thikness on immersion heaters or heat exchangers cause a loss of energy of approx.. 30%. | lime damage: washing machine, solar plants/boiler/heatings/pipes. | ||||||||||||||||||||||||||||||||
![]() |
![]() |
||||||||||||||||||||||||||||||||
| Technical Data: | Scope of supply: | ||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||
|
Corresponds to CE and EMV, to all safety and operational regulations! |
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||
| (Self Assembly) | |||||||||||||||||||||||||||||||||
|
· The protector 6.03 can be assembled on all pipe materials up to 3 inches · The protector 6.03 should be assembled between the flow meter and the distributor · The protector 6.03 can be assembled horizontally or vertically · The electronic block can also be assembled directly at the Determine the place of assembly and assemble the inductive coil in the middle, wind the cable around the pipe. The windings must lie closely together and firmly fixed on the pipe. Then assemble the two capacitive windings at the right and the left hand side of the inductive winding respectively. Fix the end of the cable at the pipe with a cable tie. |
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||
![]() |
![]() |
||||||||||||||||||||||||||||||||
![]() |
Plug the two open capacitive ends of the windings in the right and the left side of the electronics block respectively, that is the blue plugs into the blue bushings. |
||||||||||||||||||||||||||||||||
![]() |
|
Of the closed inductive winding plug one end in the left side and one end in
the right
side of the electronics block, that is the red plugs into the red bushings. Connect the line cord at the upper right side of the electronic block, that is the black 12 V-plug of theline cord into the silver bushing. |
|||||||||||||||||||||||||||||||
![]()
|
Connect the line cord at the power socket. Now the device is completely assembled. The green control display in the electronics block on the upper right is shining and the green impulse display is blinking. The display says “Water treatment activated, impulses, 1,800 Hz, 2,900 Hz, etc. up to 16,100 Hz” |
||||||||||||||||||||||||||||||||